Print: | ISSN 0256-1115 |
Online: | ISSN 1975-7220 |
Korean Journal of Chemical Engineering,
Vol.26, No.2, 542-547, 2009 Multi-method mercury specification from lignite-fired power plants
Mercury concentration and speciation partitioning, including total mercury, elemental mercury and oxidized mercury from a lignite-fired power plant under different operating conditions, was studied by Ontario hydro method (OHM), two kinds of continuous mercury monitors (semi-continuous emission monitor (SCEM) and continuous mercury monitor (CMM)), and the sorbent trap method. The effects of boiler load, fuel blending ratio, electrostatic precipitator, flue gas desulphurization, flue gas bypassing the FGD ratio, and mercury measuring methods on mercury
emission were analyzed. The results indicated that mercury data from OHM, SCEM and CMM presented a good consistency throughout the entire testing period within ±20% acceptable range; however, the results from Appendix K provided bigger discrepancies than the results of OHM and SCEM due to the interferences of higher selenium content in the flue gas. The particulate-bound mercury removal efficiencies of ESP were determined to be 16-35%. The percentages of elemental mercury emitted from two lignite-fired power plants were in the higher ranges of 43.9-74.2%.
[References]
|