Issue
Korean Journal of Chemical Engineering,
Vol.20, No.5, 799-802, 2003
The Lower Flash Points of Binary Systems Containing Non-flammable Component
The lower flash points for two binary systems (water+acetic acid and water+propionic acid) containing non-flammable component were measured by Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the Van Laar and Wilson equations. Good qualitative agreement was obtained with these equations. However, the calculated values based on the Wilson equation were found to be better than those based on the Van Laar equation.
[References]
  1. ASTM, "Standard Test Method for Flash-Point by Pensky-Martens Closed Cup Tester (ASTM D93)," American Society for Testing Materials, Philadelphia, PA, 1994
  2. Crowl DA, Louvarl JF, "Chemical Process Safety: Fundamentals with Applications," Englewood Cliffs, New York, Prentice-Hall, 1990
  3. Gmehing J, Onken U, Arlt W, "Vapor-Liquid Equilibrium Data Collection," Part1-Part7, DECHEMA, 1980
  4. Godefroy J, Jones JC, J. Loss Prevention Process Ind., 15, 241, 2002
  5. Ha DM, Mok YS, Choi JW, HWAHAK KONGHAK, 37(2), 146, 1999
  6. NFPA, "Fire Hazard Properties of Flammable Liquid, Cases and Volatile Solids," NFPA 325M, National Fire Protection Association, 1991
  7. Park JC, Ha DM, Kim MG, Korean J. Chem. Eng., 13(2), 115, 1996
  8. Reid CR, Prausnitz JM, Poling BE, "The Properties of Gases and Liquids," 4nd ed., McGraw-Hill, New York, 1998
  9. Wilson GM, J. Am. Chem. Soc., 86, 127, 1964