A high performance KIER-type CYBAGFILTER that combines a fabric filtration and centrifugal dust removal technology was developed to enhance the performance of conventional filtration systems. Based on the performance evaluation results obtained from a pilot-scale test and fluid dynamic computer simulation, a test CYBAGFILTER of 18,000 m(3)/hr capacity was installed in the clinker calcination process of Ssangyong Cement Co. located at Yongwol, Korea. Membrane filters for surface filtration were applied and evaluated. After 12-month operation, the mean pressure drop was maintained at 70-80 mmH(2)O the collection efficiency was more than 99.8%, and the outlet dust concentration was less than 5 mg/Sm-3. With an operating pressure drop of 100 mmH(2)O, the cleaning interval was much longer than that of conventional ones, promising the prolongation of filter life.
Boericke RR, Giles WG, Dietz PW, Kallio GA, Kuo JT, J. Energy, 7(1), 43, 1983
Brinchman GA, Gill RE, Hrycak MB, "The Application of GORE-TXT Membrane Bags at a Tire-to-Energy Facility," Incineration Conference Pro., Albuquerque, NM., May, 93, 1992
Frederick ER, JAPCA, 30(4), 426, 1980
Helfritch DJ, Quimby JM, "An Evaluation of a Pre-Charging Pulse-Jet Filter for Small Combustor Particulate Control," Research-Cottrell Environmental Services & Technologies, Somervill, NJ, DOE/PC/89807-T5(DE91015133), 1991
Kim SD, Park YO, Lim JH, Son JE, Jung DK, "Mathematical Simulation to Determine Optimum Module and Fluid Dynamic Characteristics of KIER Type CYBAGFILTER," Theories and Application of Chemical Engineering, Proceedings of '98 KIChE Spring Meeting, 5, 865, 1999
Kim SD, Park YO, Lim JH, Son JE, Jung DK, "Optimum Design of Inner Tube Type in KIER Type CYBAGFILTER," Theories and Application of Chemical Engineering, Proceedings of '98 KIChE Fall Meeting, 4, 2801, 1998
Miller SJ, Schelkoph GL, Dunham GE, Walker K, Krigmont K, "Advanced Hybrid Particulate Collector, A New Concept for Air Toxics and Fine-particle Control," EPRI-DOE-EPA Combined Utility, Air Pollutant Control Mega Sym, Washington, D.C., Aug. 25-29, 1997
Park YO, Choi HK, Kim SD, Lim JH, Son JE, "Development of High Efficiency Compact Hybrid Filtering System of Dust Precharging and Membrane Coated Filters," The Ministry of Commerce, Industry and Energy, 1997-C-CC02-P-02, 105, 1999
Park YO, Kim SD, Lim JH, Choi HK, Kil IS, Son JE, "Performance Characteristics of KIER Type CYBAGFILTER," Proceedings, 1st Korean Conference on Aerosol and Particle Technology, 241, 1999
Park YO, J. Korea Air Pollution Res. Assoc., 8(1), 16, 1995
Son JE, Choi HK, Kim SD, Lim JH, Park YO, "Development of Domestic High Efficiency Fabric Filter System for Industries," The Ministry of Environment, KIER-976621, 530, 1998