Issue
Korean Journal of Chemical Engineering,
Vol.37, No.6, 1057-1065, 2020
Enhanced separation performance of three-zone simulated moving bed chromatography with ModiCon strategy
A three-zone simulated moving bed (SMB) chromatography using ModiCon strategy is proposed to enhance the separating performance. In this approach, three fold-concentrated feed and only desorbent are introduced during one-third and two-thirds of the switching time, respectively. The results showed that if the concentrated feed is introduced during the first and the last subsection of switching time, purity of extract and raffinate are improved, respectively, while recovery and other performance indices (i.e., solvent consumption and ratio of desorbent/feed) are slightly decreased. On the other hand, introduction of concentrated feed during the middle subsection of switching time results in an increase of both raffinate and extract purity, as well as the recovery yield. Other performance indices were comparable to those of three-zone SMB without ModiCon.
[References]
  1. Miller L, Grill C, Yan T, Dapremont O, Huthmann E, Juza M, J. Chromatogr. A, 1006, 267, 2003
  2. Broughton DB, Gerhold CG, U.S. Patent, 2,985,589 (1961).
  3. Broughton DB, Chem. Eng. Prog., 66, 70, 1970
  4. Gomes PS, Rodrigues AE, Chem. Eng. Technol., 35(1), 17, 2012
  5. Faria RPV, Rodrigues AE, J. Chromatogr. A, 1421, 82, 2015
  6. Hashimoto K, Yamada M, Adachi S, Shirai Y, J. Chem. Eng. Jpn., 22, 432, 1989
  7. Zang YF, Wankat PC, Ind. Eng. Chem. Res., 41(21), 5283, 2002
  8. Chin CY, Wang NHL, Sep. Purif. Rev., 33, 77, 2004
  9. Ludemann-Hombourger O, Nicoud RM, Bailly M, Sep. Sci. Technol., 35(12), 1829, 2000
  10. Ludemann-Hombourger O, Pigorini G, Nicoud RM, Ross DS, Terfloth G, J. Chromatogr. A, 947, 59, 2002
  11. Zang YF, Wankat PC, Ind. Eng. Chem. Res., 41(21), 5283, 2002
  12. Zhang Z, Mazzotti M, Morbidelli M, J. Chromatogr. A, 1006, 87, 2003
  13. Zhang ZY, Morbidelli M, Mazzotti M, AIChE J., 50(3), 625, 2004
  14. Schramm H, Kienle A, Kaspereit M, Seidel-Morgenstern A, Chem. Eng. Sci., 58(23-24), 5217, 2003
  15. Schramm H, Kaspereit M, Kienle A, Seidel-Morgenstern A, J. Chromatogr. A, 1006, 77, 2003
  16. Yu YY, Wood KR, Liu YA, Ind. Eng. Chem. Res., 54(46), 11576, 2015
  17. Zhang Z, Mazzotti M, Morbidelli M, Korean J. Chem. Eng., 21(2), 454, 2004
  18. Mun S, J. Chromatogr. A, 1341, 8, 2014
  19. Tangpromphan P, Budman H, Jaree A, Chem. Eng. Process., 126, 23, 2018
  20. Shen B, Chen MJ, Jiang HL, Zhao YX, Wei F, Sep. Sci. Technol., 46(5), 695, 2011
  21. Nam HG, Park C, Jo SH, Suh YW, Mun S, rocess Biochem., 47, 2418, 2012
  22. Storti G, Mazzotti M, Morbidelli M, Carra S, AIChE J., 39, 471, 1993
  23. Aroso IM, Craveiro R, Rocha A, Dionisio M, Barreiros S, Reis RL, Paiva A, Cuarte ARC, Int. J. Pharm., 492, 73, 2015
  24. Wilson EJ, Geankoplis CJ, Ind. Eng. Chem. Fundam., 5, 9, 1966