Korean Journal of Chemical Engineering, Vol.14, No.2, 101-108, 1997
SIGNAL ANALYSIS OF FIBER-OPTIC BIOSENSOR FOR THE DETECTION OF ORGANOPHOSPHORUS COMPOUNDS IN THE CONTAMINATED WATER
The fiber-optic biosensor consisted of tubular enzyme reactor and two sensing parts was developed for the detection of organophosphorus compounds in a contaminated water. The organophosphorus compounds was measured by acetylcholinesterase entrapped by Ca-alginate gel on a silicon tube. The litmus dye was used as the indicator of color change due to the inhibition of organophosphorus compounds on the acetylcholinesterase. Transmittance change of light at the input and output parts of tubular enzyme reactor was detected. The biosensor has the linear analytical range of 0-1.0 ppm with response time of 5 minutes. The proposed kinetics for irreversible inhibition of organophosphorus compounds on AChE agreed well with the experimental data. The theoretical model of diffusion and reaction in enzyme membrane was presented to analyze the response of sensor signal. Based on the simulation results using the model, the optimal amount of enzyme loaded and substrate was obtained as 80 Ռg and 6 mM, respectively.
[References]
- Abdel-Latif MS, Guidbault GG, "Fiber Optic-Based Biosensors Utilizing Immobilized Enzyme Systems," Biosensor Technology: Fundamentals and Applications, Buck, R.P., Hatfield, W.E., Umana, M. and Bowden, E.F., eds., Marcel Dekker, New York, 1990
- Alfthan K, Kenttamaa H, Zukale T, Anal. Chim. Acta, 217, 43, 1989
- Carome EF, Coghlan GA, Sukenik CN, Zull JE, Sens. Actuators B-Chem., 13-14, 732, 1993
- Choi US, Cho KM, "Environmental Engineering," Cheongmungak, Seoul, 1990
- Dumschat C, Muller H, Stein K, Schwedt G, Anal. Chim. Acta, 252, 7, 1991
- Klaimer SM, Thomas JR, Franels JC, Sens. Actuators B-Chem., 11, 81, 1993
- Leon-Gonzalez ME, Townshend A, Anal. Chim. Acta, 236, 267, 1990
- Maron MJ, "Numerical Analysis; A Practical Approach," Macmillan, New York, 1982
- Metzler CM, Elfring GL, McEwen AJ, Biometrics, 30, 562, 1974
- Perry RH, Green D, "Perry's Chemical Engineering's Handbook," McGraw-Hill, New York, 1984
- Skladal P, Anal. Chim. Acta, 252, 11, 1991
- Takruni IA, Almuaibed AM, Townshend A, Anal. Chim. Acta, 282, 307, 1993
- Trettnak W, Hofer M, Wolfbeis OS, "Applications of Optochemical Sensors for Measuring Environmental and Biochemical Quantities," Sensors, Vol. 3, Gopel, W., Hesse, J. and Zemel, J.N., Eds., VCH, New York, 1991
- Trettnak W, Reinninger F, Zinterl E, Wolfbeis OS, Sens. Actuators B-Chem., 11, 87, 1993
- Tyrrell HIV, Harris KR, "Diffusion on Liquids," Butterworths, London, 1984
- Villadsen J, Michelsen ML, "Solution of Differential Equation Models by Polynomial Approximation," Prentice-Hall, Englewood Cliffs, 1978
- Wittmann C, Schmid RD, Sens. Actuators B-Chem., 15-16, 119, 1993
- Westrin BA, Axelsson A, Biotechnol. Bioeng., 38, 439, 1991
- Wolfbeis OS, Koller E, "Fiber Optic Detection of Pesticides in Drinking Water," Biosensors Application in Medicine, Environmental Protection and Process Control, Schmid, R.D. and Scheller, F., eds., GBF, New York, 1989
[Cited By]
- Kim J, Kim J, Shin Y, Yoon Y, Korean Journal of Chemical Engineering, 18(1), 61, 2001
- Hyun JY, Lee GS, Kim TY, Ahn DJ, Korean Journal of Chemical Engineering, 14(6), 533, 1997
- Song HM, Lee CS, Korean Journal of Chemical Engineering, 25(6), 1467, 2008
|