Korean Journal of Chemical Engineering, Vol.29, No.12, 1666-1669, 2012
Use of biologically designed gold nanowire for biosensor application
A highly sensitive tyrosinase (TYR)-based amperometric biosensor is prepared using biologically designed gold nanowires (AuNWs) for pesticide detection. The AuNWs were synthesized by dodecapeptide Midas-11 and were modified with the formation of self-assembled monolayer (SAM), followed by covalent binding with TYR. The prepared TYR-AuNWs-SPCE (screen printed carbon electrode) was compared with bare, AuNWs-, modified-AuNWs-SPCE
by the measurement of cyclic voltammetry. The quantitative relationship between the inhibition percentage and the pesticide concentration at the TYR-AuNWs-SPCE was obtained by measuring the current response in various concentrations of pesticides. The reasonable detection range of parathion was determined to be 0.1 ppt through 10 ppb (R2=0.990) with 0.087 ppt of detection limits. The higher sensitivity and wider detection range of the TYR-based biosensor was achieved by the use of biologically synthesized AuNWs.
[References]
- Llorent-Martinez EJ, Ortega-Barrales P, Fernandez-de Cordova ML, Ruiz-Medina A, Anal. Chim. Acta., 684, 30, 2011
- Boye B, Brillas E, Marselli B, Michaud PA, Comninellis C, Farnia G, Sandona G, Electrochim. Acta, 51(14), 2872, 2006
- Cha DK, Sarr D, Chiu PC, Kim DW, Water Environ. Res., 70, 705, 1998
- Van Dyk JS, Pletschke B, Chemosphere., 82(3), 291, 2011
- de Albuquerque YDT, Ferreira LF, Anal. Chim. Acta., 596, 210, 2007
- Lee HS, Kim YA, Cho YA, Lee YT, Chemosphere., 46, 571, 2002
- Shi MH, Xu JJ, Zhang S, Liu BH, Kong JL, Talanta., 68, 1089, 2006
- Joshi KA, Tang J, Haddon R, Wang J, Chen W, Mulchandani A, Electroanalysis., 17, 54, 2005
- Kia M, Islamnezhad A, Shariati S, Biparva P, Korean J. Chem. Eng., 28(10), 2064, 2011
- Kim GY, Shim J, Kang MS, Moon SH, J. Hazard. Mater., 156(1-3), 141, 2008
- Park BW, Kim DS, Yoon DY, Korean J. Chem. Eng., 28(1), 64, 2011
- Liu GD, Wang J, Barry , Petersen C, Timchalk C, Gassman PL, Lin YH, Chem. Eur. J., 14, 9951, 2008
- Katz E, Willner I, Wang J, Electroanalysis., 16, 19, 2004
- Umasankar Y, Chen SM, Sensors., 8, 290, 2008
- Cherevko S, Chung CH, Sensors and Actuators, B: Chemical., 142, 216, 2009
- Kim J, Rheem Y, Yoo B, Chong Y, Bozhilov KN, Kim D, Sadowsky MJ, Hur HG, Myung NV, Acta Biomater., 6, 2681, 2010
- Kim GY, Shim J, Kang MS, Moon SH, J. Environ. Monit., 10, 632, 2008
- Gorelik LY, Voinova MV, Biosens. Bioelectron., 22, 405, 2006
- Shim J, Woo JJ, Moon SH, Kim GY, J. Membr. Sci., 330(1-2), 341, 2009
- Lin YH, Lu F, Wang J, Electroanalysis., 16, 145, 2004
- Du D, Huang X, Cai H, Zhang AD, Biosens. Bioelectron., 23, 285, 2007
- Abad JM, Pariente F, Hernandez L, Abruna HD, Lorenzo E, Anal. Chem., 70, 2848, 1998
- Viswanathan S, Radecka H, Radecki J, Biosens. Bioelectron., 24, 2772, 2009
|