articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

Most Cited

Performance of Single-Chamber Microbial Fuel Cells Based on the Air Cathode of Hydrophobicity of Carbon Black/Polytetrafl uoroethylene Gas Diff usion Layer

School of Environment and Ecology , Jiangnan University 1Jiangsu Key Laboratory of Anaerobic Biotechnology 2Jiangsu Cooperative Innovation Center of Technology and Material of Water Treatment 3College of Environmental Science and Engineering , Qilu University of Technology (Shandong Academy of Sciences)
hruicao@163.com
Korean Journal of Chemical Engineering, July 2025, 42(8), 000042
https://doi.org/10.1007/s11814-025-00468-3

Abstract

The eff ect of hydrophobicity of the gas diff usion layer on the performance of a single-chamber microbial fuel cell was

investigated. The R4 (3:1) reactor showed the best performance with a maximum power density of 1431 ± 80.3 mW m −2

and a coulombic effi ciency of 45%. Scanning electron microscopy revealed that the gap between carbon black particles

increased with decreasing PTFE ratio. Electrochemical analysis showed that the activated carbon/stainless-steel mesh/(CB/

PTFE) electrode performed the best with the highest current density of 8.09 A m −2 . High-performance recovery (88%) of the

contaminated electrode was achieved using lysozyme (5%) remediation method. In addition, the R4 (3:1) electrode was the

most suitable choice as an air cathode for SC-MFC, with a fabrication cost of 17.71 $ m −2 . In conclusion, this study provides

valuable insights into the preparation and optimization of air cathodes for MFCs, which can contribute to the development

of future MFC technologies.