ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Overall

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received June 19, 2017
Accepted August 9, 2017
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

Most Cited

Highly sensitive glucose biosensor using new glucose oxidase based biocatalyst

Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
Korean Journal of Chemical Engineering, November 2017, 34(11), 2916-2921(6), 10.1007/s11814-017-0224-9
downloadDownload PDF

Abstract

Glucose, which is a primary energy source of living organisms, can induce diabetes or hypoglycemia if its concentration in blood is irregular. It is therefore important to develop glucose biosensor that reads the concentration of glucose in blood precisely. In the present work, we suggest new glucose oxidase (GOx) based catalysts that can improve the sensitivity of the glucose biosensor and make glucose measurements over a wide concentration ranges possible. For synthesizing such catalysts, a composite including pyrenecarboxaldehyde (PCA) and GOx is attached to substrate including carbon nanotube (CNT) and polyethyleneimine (PEI) (CNT/PEI/[PCA/GOx]). Catalytic activity and stability of the catalyst are then evaluated. According to the investigation, the catalyst shows excellent glucose sensitivity of 47.83 μAcm-2mM-1, low Michaelis-Menten constant of 2.2mM, and wide glucose concentration detection, while it has good glucose selectivity against inhibitors, such as uric acid and ascorbic acid. Also, its activity is maintained to 95.7% of its initial value even after four weeks, confirming the catalyst is stable enough. The excellence of the catalyst is attributed to hydrophobic interaction, C=N bonds, and π-hydrogen interaction among GOx, PCA and PEI/ CNT. The bindings play a role in facilitating electron transport between GOx and electrode.

References

Wang J, Chem. Rev., 108(2), 814 (2008)
Chung Y, Kwon Y, Korean Chem. Eng. Res., 53(6), 802 (2015)
World Health Organization (WHO) of United Nations (UN). Global Report on Diabetes sheet. Available online: http://www.who.int/diabetes/global-report/WHD16-press-release-EN_3.pdf (Accessed on May 09, 2016).
Clark LC, Lyons C, Ann NY, Acad. Sci., 102, 29 (1962)
Cosnier S, Biosens. Bioelectron., 14, 443 (1999)
Minteer SD, Liaw BY, Cooney MJ, Curr. Opin. Biotechnol., 18, 228 (2007)
Kim J, Jia H, Wang PC, Biotechnol. Adv., 24, 296 (2006)
Zhou C, Xu L, Song J, Xing R, Xu S, Liu D, Song H, Sci. Rep., 4, 7382 (2014)
Zhu H, Li L, Zhou L, Shao Z, Chen X, J. Mater. Chem., 4, 7333 (2016)
Christwardana M, Kwon Y, J. Power Sources, 299, 604 (2015)
Barton SC, Gallaway J, Atanassov P, Chem. Rev., 104(10), 4867 (2004)
Yu EH, Krewer U, Scott K, Energy, 3, 1499 (2010)
Choi HS, Kim DS, Thapa LP, Lee SJ, Kim SB, Cho J, Park C, Kim SW, Korean J. Chem. Eng., 33(12), 3434 (2016)
Bohara RA, Thorat ND, Pawar SH, Korean J. Chem. Eng., 33(1), 216 (2016)
Inamuddin, Beenish, Naushad M, Korean J. Chem. Eng., 33(1), 120 (2016)
Jo BH, Kim CS, Jo YK, Cheong H, Cha HJ, Korean J. Chem. Eng., 33(4), 1125 (2016)
Christwardana M, Chung Y, Kwon Y, NPG Asia Mater., 9, e386 (2017)
Chung Y, Ahn Y, Kim DH, Kwon Y, J. Power Sources, 337, 152 (2017)
Christwardana M, Chung Y, Kwon Y, Nanoscale., 9, 1993 (2017)
Hyun KH, Han SW, Koh WG, Kwon Y, J. Power Sources, 286, 197 (2015)
Wooten M, Karra S, Zhang M, Gorski W, Anal. Chem., 86, 752 (2014)
Cui JD, Liu RL, Li LB, Korean J. Chem. Eng., 33(2), 610 (2016)
Hyun K, Han SW, Koh WG, Kwon Y, Int. J. Hydrog. Energy, 40(5), 2199 (2015)
Christwardana M, Kim KJ, Kwon Y, Sci. Rep., 6, 3012 (2016)
Yoo EH, Lee SY, Sensors, 10, 4558 (2010)
Uang YM, Chou TC, Biosens. Bioelectron., 19, 141 (2003)
Liu Y, Wang M, Zhao F, Xu Z, Dong S, Biosens. Bioelectron., 21, 984 (2005)
Kong T, Chen Y, Ye Y, Zhang K, Wang Z, Wang X, Sens. Actuators B-Chem., 138, 344 (2009)
Kang X, Wang J, Wu H, Aksay IA, Liu J, Lin Y, Biosens. Bioelectron., 25, 901 (2009)
Liu G, Lin Y, Electrochem. Commun., 8, 251 (2006)
Wu BY, Hou SH, Yin F, Li J, Zhao ZX, Huang JD, Chen Q, Biosens. Bioelectron., 22, 838 (2007)
Unnikrishnan B, Palanisamy S, Chen SM, Biosens. Bioelectron., 39, 70 (2013)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로