ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

OXYGEN TRANSFER ANALYSIS IN A DUAL HOLLOW-FIBER BIOREACTOR SYSTEM

Korean Journal of Chemical Engineering, March 1988, 5(1), 83-85(3), 10.1007/BF02697481
downloadDownload PDF

Abstract

Oxygen transfer analysis in a dual hollow-fiber bioreactor system was carried out by simulation. Oxygen penetration depth and volumetric oxygen uptake rate were not much affected by the silicone membrane thickness and major portion of oxygen transfer resistance existed in the immobilized cell layer.

Keywords

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로