ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2025 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received January 31, 2014
Accepted July 9, 2014
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Drying performance of a dishwasher with internal air circulation

School of Chemical Engineering, Sungkyunkwan University, 2066, Seobu-ro, Jangan, Suwon 440-746, Korea
dhlee@skku.edu
Korean Journal of Chemical Engineering, September 2014, 31(9), 1518-1521(4)
https://doi.org/10.1007/s11814-014-0194-0
downloadDownload PDF

Abstract

This paper presents an experimental study on the energy flow and drying performance of a dishwasher with internal air circulation. A simple energy flow process was established to determine the energy consumption of a dishwasher with internal air circulation. The drying performance of the dishwasher was determined by evaluating dish wetness. The effect of various performance variables (e.g., final rinse temperature, air circulation flow rate, and fan operation time) on the drying performance and the energy consumption was assessed individually. All tests were performed following a slightly modified EN50242. The energy accumulated in the final rinse step was responsible for evaporating water off dishes. The drying performance increased as the energy consumption increased. More than 1.17 kWh energy was consumed to obtain a drying performance greater than 1.8.

References

Bansal P, Vineyard E, Abdelaziz O, Appl. Therm. Eng., 31(17-18), 3748 (2011)
De Paepe M, Theuns E, Lenaers S, van Loon J, Appl. Therm. Eng., 23, 743 (2003)
Lin S, Broadbent J, McGlen R, Appl. Therm. Eng., 25, 127 (2005)
Persson T, Appl. Therm. Eng., 27, 120 (2007)
EN50242 Electric dishwashers for household use-Methods for measuring the performance (2008)
McAdams WH, Heat Transmission, 3rd Ed., McGraw-Hill (1954)

The Korean Institute of Chemical Engineers. F5,119, Anam-ro, Seongbuk-gu, Seoul, Republic of Korea
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로