articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Viscous dissipation effect on heat transfer characteristics of mixed electromagnetic/pressure driven liquid flows inside micropumps

Mechatronics Engineering Program, Faculty of Engineering and Natural Sciences, Sabanci University, Tuzla, Istanbul 34956, Turkey 1Department of Mechanical and Aerospace Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
Korean Journal of Chemical Engineering, April 2013, 30(4),
10.1007/s11814-012-0233-9
downloadDownload PDF

Abstract

This paper presents the effect of viscous dissipation on heat transfer characteristics of mixed electromagnetic/pressure driven liquid slip flows inside parallel plate microchannels. Flow is governed by the Navier-Stokes equations subject to the imposition of electromagnetic field with the boundary condition appropriate to the slip flow regime. For isoflux walls, some closed form expressions for the local and bulk temperature profiles and the Nusselt number in terms of dimensionless slip length, Hartmann number and Brinkman number are given, while the viscous dissipation is also taken into account. Then the analytical solutions derived in this analysis are elaborated. It turns out that since the contribution of the viscous dissipation on the Nusselt number under the given circumstances, especially a stronger electromagnetic field, may reach to nearly 10%, therefore, the viscous heating should be taken into consideration. Otherwise, the heat transfer rate may be overestimated or underestimated depending on whether the fluid is being heated or cooled. Also, there are singularities in Nusselt number values, which move close together by including the viscous dissipation. Further, an increase in the Hartmann number increases the convection, which is especially reflected in smaller values of dimensionless slip length.

References

Bailey DK, Ameel TA, Warrington RO, Savoie TI, Proceedings of the IECEC Conference, ES-396, ASME-FL, Orlando (1995)
Duncan AB, Peterson GP, Appl. Mech. Rev., 47, 397 (1994)
Morini GL, Int. J. Therm. Sci., 43, 631 (2004)
Chun MS, Lee S, Colloids Surf. A., 267, 86 (2005)
Joseph P,Tabeling P, Phys. Rev. E.
Tretheway DC, Meinhart CD, Phys. Fluids., 14, 9 (2002)
El-Genk M, Yang I, J. Heat Trans.-ASME., 082405-1, 130 (2008)
Kavehpour HP, Faghri M, Asako Y, Numer. Heat Trans. Part A., 32, 677 (1997)
Ngoma GD, Erchiqui F, Int. J. Therm. Sci., 46, 1076 (2007)
Shams M, Shojaeian M, Aghanajafi C, Dibaji SAR, Int. Commun. Heat Mass Trans., 36, 1075 (2009)
Shojaeian M, Dibaji SAR, Int. Commun. Heat Mass Trans., 37, 324 (2010)
Xu B, Ooi KT, Mavriplis C, Zaghloul ME, J. Micromech.Microeng., 13, 53 (2003)
Aynur TN, Kuddusi L, Egrican N, Heat Mass Trans., 42, 1093 (2006)
Chen CH, Heat Mass Trans., 42, 853 (2006)
Hooman K, Int. Commun. Heat Mass Trans., 34, 945 (2007)
Koo J, Kleinstreuer C, J. Micromech. Microeng., 13, 568 (2003)
Koo J, Kleinstreuer C, Int. J. Heat Mass Transf., 47(14-16), 3159 (2004)
Rij JV, Ameel T, Harman T, Int. J. Therm. Sci., 48, 271 (2009)
Sadeghi A, Saidi MH, J. Heat Trans.-ASME., 132, 072401 (2010)
Tso CP, Mahulikar SP, Int. J. Heat Mass Transf., 41(12), 1759 (1998)
Alpher RA, Int. J. Heat Mass Trans., 3, 108 (1961)
Ghassemi M, Rezaeinezhad H, Shahidian A, Proceedings of 14th symposium on electromagnetic launch technology, June, Victoria, 1 (2008)
Gupta RC, Mech. Res. Commun., 19, 73 (1992)
Verardi SLL, Machado JM, Cardoso JR, IEEE Transaction Magnetics., 38, 941 (2002)
Andreev O, Kolesnikov Y, Thess A, Phys. Fluids., 18, 065108 (2006)
Andreev O, Kolesnikov Y, Thess A, Exp. Fluids., 46, 77 (2009)
Chen H, Zhoub T, Yangb Z, Lub R, Zhub Z, Ni M, Fusion Eng. Des., 85, 1742 (2010)
Duwairi H, Abdollah M, Microsyst. Technol., 13, 33 (2007)
Jang J, Lee SS, Sensor. Actuat. A., 80, 84 (2000)
Lemoff AV, Lee AP, Sensor. Actuat. B., 63, 178 (2000)
Wang PJ, Chang CY, Chang ML, Biosens. Bioelectron., 20, 115 (2004)
Siegel AC, Bruzewicz DA, Weibel DB, Whitesides GM, Adv. Mater., 19(5), 727 (2007)
Siegel AC, Shevkoplyas SS, Weibel DB, Bruzewicz DA, Martinez AW, Whitesides GM, Angew. Chem. Int. Ed., 45, 6877 (2006)
Dickey MD, Chiechi RC, Larsen RJ, Weiss EA, Weitz DA, Whitesides GM, Adv. Funct. Mater., 18(7), 1097 (2008)
Qian SZ, Bau HH, Mech. Res. Commun., 36, 382 (2009)
Soundalgekar VM, Proc. Natl. Inst. Sci. India Part A., 33, 276 (1967)
Soundalgekar VM, Proc. Natl. Inst. Sci. India Part A., 135, 251 (1969)
Soundalgekar VM, Proc. Natl. Inst. Sci. India Part A., 35, 439 (1969)
Cai C, Liu D, AIAA J., 47, 542 (2009)
Shojaeian M, Shojaeian M, Microfluid. Nanofluid., 12, 553 (2012)
Agarwal RK, Proceedings of 36th AIAA Plasmadynamics and Lasers Conference, AIAA, Toronto, 2005-4782 (2005)
Navier CLMH, Mem. Acad. R. Sci. Inst., France., 1, 414 (1823)

The Korean Institute of Chemical Engineers. F5,119, Anam-ro, Seongbuk-gu, Seoul, Republic of Korea
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로