ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received July 13, 2011
Accepted November 6, 2011
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Estimation of nitrous oxide emissions (GHG) from wastewater treatment plants using closed-loop mass balance and data reconciliation

Department of Environmental Science and Engineering, Center for Environmental Studies, Kyung Hee University, 1, Seocheon-dong, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea 1Department of Architectural Engineering, Kyung Hee University, 1, Seocheon-dong, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
Korean Journal of Chemical Engineering, September 2012, 29(9), 1123-1128(6), 10.1007/s11814-011-0283-2
downloadDownload PDF

Abstract

The amount of greenhouse gases (GHG), especially, nitrous oxide (N2O) emitted from wastewater treatment plants (WWTP) using data reconciliation and closed-loop mass balance was estimated. This study is based on a flowbased emission estimation approach which depends on the accuracy of the measurement data. To reduce the (random) measurement error, data reconciliation was used to enhance the accuracy of the flow measurements. After performing data reconciliation, N2O emission was estimated with more precision by using the closed-loop mass balance. The results in both pilot-scale and full-scale plants show that the suggested method can easily obtain the precise flow measurement for GHG emission, which in turn, results in the accurate estimation of the N2O amounts emitted from WWTP. Moreover, it is shown that the estimated flowrate values can be used as a software sensor, which can replace the faulty sensors and can validate the existing field measurements.

References

Liu X, Peng Y, Wu C, Akio T, Peng Y, J. Environ. Sci., 20, 614 (2008)
Czepiel P, Crill P, Harriss R, Environ. Sci. Technol., 29, 2352 (1995)
Foley J, de Haas D, Yuan Z, Lant P, Water Res., 44, 831 (2010)
Nowak O, Franz A, Svardal K, Muller V, Kuhn V, Water Sci.Technol., 39, 133 (1999)
Romagnoli JA, Sanchez MC, Data processing and reconciliation for chemical process operation, Academic Press, USA (2000)
Meijer SCF, van der Spoel H, Susanti S, Heijnen JJ, van Loosdrecht MCM, Water Sci. Technol., 45, 145 (2002)
Rieger L, Takacs I, Villez K, Siegrist H, Lessard P, Vanrolleghem PA, Comeau Y, Water Environ. Res., 82, 426 (2010)
Puig S, van Loosdrecht MCM, Colprim J, Meijer SCF, Water Res., 40, 4645 (2008)
2006 IPCC Guidelines for national greenhouse gas inventories, Japan (2006)
Kampschreur MJ, Temmink H, Kleerebezem R, Jetten MSM, Loosdrecht MCM, Water Res., 43, 4093 (2009)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로