articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Evaluation of mixing conditions using an on-line monitoring technique

Water Quality Institute, Busan City Waterworks, Gimhae 621-813, Korea 1Civil Engineering Department, Kyungnam University, Masan 631-701, Korea 2Dept. of Civil & Environ. Eng, Cheju National University, Jeju 690-756, Korea
Korean Journal of Chemical Engineering, January 2008, 25(1), 19-24(6), 10.1007/s11814-008-0004-7
downloadDownload PDF

Abstract

Effects of mixing conditions on flocculation were investigated by using a photometric dispersion analyzer (PDA) as an on-line monitoring technique in this study. Both river water and synthetic waters of humic acid (HA) and kaolin solutions were used and polyaluminum chloride (PACl) were used as a coagulant in this study. A clear relationship between F-index and residual turbidity was observed. Residual turbidity was low at high F-index. The mixing effects were also found closely related to the floc formation. When the floc formation was governed by a combination of charge neutralization and sweep floc, rapid mixing was important, but it was not important when the floc formation was governed by the sweep floc mechanism. The coagulant dosage governed the floc size and strength in the sweep floc region. The higher the coagulant dosage was, the larger but the weaker the floc was. Rapid mixing effects were different, depending on raw water characteristics. Fast and large floc formation was observed in flocculation of the kaolin solution, compared to that of the HA solution. Small HA would be mostly adsorbed onto the hydroxide precipitate after the precipitate formed. The adsorption could retard further floc growth. The resulting floc was small, and the floc formation was slow. However, kaolin helped flocculation by bridging the hydroxide precipitates, leading to fast and large floc formation. Temperature affected the flocculation kinetics as well as the floc size. A large floc formed at high temperature. The flocculation kinetics became fast with increasing temperature.

References

Stumm W, O’melia CR, J. AWWA, 60, 514 (1968)
Vik EA, Eikebrokk B, Coagulation process for removal of humic substances from drink water in a aquatic substance: Influence of Fate and treatment of pollutions, I. H. Suffet and P. A. Mac-Carthy Eds., 385-408, Symposium by the American Chemical Society, Washington, D.C.
Amirtharajah A, Mills KM, J. AWWA, 74, 210 (1982)
Camp TR, Stein PC, J. Boston Soc. Civil Eng., 30, 219 (1943)
Gregory J, J. Colloid Interface Sci., 105, 357 (1985)
Gregory J, Colloids Surf., 18, 175 (1986)
Burgess MS, Curely JE, Wiseman N, Kamei T, J. Pulp Pap. Sci., 28, 63 (2002)
Kan C, Huang C, Pan JR, Colloids and Surfaces A; Physicochemical and Engineering Aspect, 203, 1 (2002)
Hopkins DC, Ducoste JJ, J. Colloid Interface Sci., 264(1), 184 (2003)
Wang J, J. AWWA, 93, 54 (2001)
Briley DS, Knappe, Detlef RU, J. AWWA, 94, 80 (2002)
Fitzpatrick CSB, Fradin E, Gregory J, Water Sci. Technol., 171 (2004)
Gregory J, Chem. Eng. Sci., 36, 1789 (1981)
Gregory J, Chung H, J. Water SRT-Aqua, 44, 125 (1995)
Hutchinson WR, Foley PD, J. AWWA, 66, 79 (1974)
Hutchinson WR, J. AWWA, 68, 79 (1976)
Jung HJ, Lee JW, Choi DY, Kim SJ, Kwak DH, Korean J. Chem. Eng., 23(2), 271 (2006)
Kim DJ, Kim KS, Korean J. Chem. Eng., 19(3), 495 (2002)
Kim JP, Han IS, Chung CB, Korean J. Chem. Eng., 20(3), 580 (2003)
Sweeny GE, Prendiville PM, J. AWWA, 66, 65 (1974)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로