Issue
Korean Chemical Engineering Research,
Vol.52, No.6, 775-780, 2014
Micellar Enhanced Ultrafiltration (MEUF) and Activated Carbon Fiber (ACF) Hybrid Processes for the Removal of Cadmium from an Aqueous Solution
Micellar enhanced ultrafiltration (MEUF) was used to remove cadmium from an aqueous solution using sodium dodecyl sulfate (SDS) as a surfactant. Operational parameters such as initial permeate flux, retentate pressure, initial cadmium concentration, pH solution, molecular weight cut-off (MWCO), and molar ratio of cadmium to SDS were investigated. Removal efficiency of cadmium from an aqueous solution increased with an increase of retentate pressure, pH solution and molar ratio of cadmium to SDS, and decreased with an increase of initial permeate flux. Higher removal efficiency of cadmium from the aqueous solution was achieved using lower MWCO (smaller membrane pore size). Under optimized experimental condition, cadmium removal efficiency reached 74.6 % within an hour. Using MEUF-ACF hybrid process the removal efficiency of both cadmium and SDS was found to be over 90%.
[References]
  1. Frontasyeva MV, Perelygin VP, Vater P, Radionuclides and heavy metals in environment, 1st ed., Kluwer Academic Publishers, Netherlands, 2001
  2. Baek K, Kim BK, Cho HJ, Yang JW, J. Hazard. Mater., 99(3), 303, 2003
  3. Environmental Defense Fund (EDF) via USEPA Envirofacts Data Base (www.scorecard.org/chemical-profiles/).
  4. Xu K, Zeng GM, Huang JH, et al., Colloids Surf. A: Physicochem. Eng. Asp. Aspects, 294, 140, 2007
  5. Purkait MK, Gupta SD, De S, J. Colloid Interface Sci., 207, 496, 2004
  6. Christian SD, Scamehorn JF, Ellington RT, Harwell JH (Eds.), Surfactant based separation processes, Marcel Dekker. New York, (chapter 1), 1989
  7. Scamehorn JF, Harwell JH, Wason DT, Ginn MF, Shah DO, Surfactants in chemical process engineering. Marcel Dekker, New York, (chapter 3), 1998
  8. Basar CA, Karagunduz A, Cakici A, Keskinler B, Water Res., 38, 2117, 2004
  9. Li JW, Yu Z, Gao M, Cai Z, Water Air Soil Pollut., 97, 367, 1997
  10. El-Sharkawy II, Saha BB, Koyama S, Ng KC, Int. J. Heat Mass Transf., 49(17-18), 3104, 2006
  11. APHA, American Public Health Association, Washington D.C., 1998
  12. Ghosh G, Bhattacharya PK, Chem. Eng. J., 119(1), 45, 2006
  13. Gzara L, Dhahbi M, Desalination, 137(1-3), 241, 2001
  14. Bade R, Lee SH, Jo S, Lee HS, Lee SE, Desalination, 229(1-3), 264, 2008
  15. Baek K, Yang JW, Korean J. Chem. Eng., 21(5), 989, 2004
  16. Bade R, Lee SH, Korean J. Chem. Eng., 24(2), 239, 2007
  17. Channarong B, Lee SH, Bade R, Shipin OV, Desalination, 262(1-3), 221, 2010
  18. Qu YH, Zeng GM, Huang JH, Li M, Fang YY, Zhang Z, Ind. Water Wastewater(in China), 37(6), 12, 2006
  19. Beolchini F, Pagnanelli F, De Michelis I, Veglio F, J. Hazard. Mater., 148(1-2), 116, 2007