Issue
Korean Journal of Chemical Engineering,
Vol.29, No.1, 9-17, 2012
Dynamic simulation based fault detection and diagnosis for distillation column
The model-based fault diagnosis approach is characterized by a powerful process supervision capability with a priori knowledge about the system under consideration. Nevertheless, system complexity, high dimensionality, process nonlinearity and/or lack of good data often hamper its application in chemical engineering systems. A nonsteady state model based fault detection and diagnosis method for the distillation process was developed, using dynamic simulation to monitor the distillation process and identify abnormal sources when large deviations among measuring variables occur. It continuously updates the inner distillation parameters via on-line correction and predicts the trend of measuring variables and determines the existence of malfunctions simultaneously. The distillation model is dependent on transfer equilibrium, mass and heat balance, and is simulated by Euler and two-tier approach. This method was demonstrated with simulated data of a stripping tower collected from the Tennessee Eastman chemical plant simulator.
[References]
  1. Kim MH, Yoo CK, Korean J. Chem. Eng., 25(5), 947, 2008
  2. Venkatsubramanian V, Rengaswamy R, Yin K, Kavuri SN, Comput. Chem. Eng., 27(3), 293, 2003
  3. Ding YF, Xu WD, Pan F, Computer Eng., 30(23), 171, 2004
  4. Koo J, Kim S, Kim H, Kim YH, Yoon ES, Korean J. Chem. Eng., 26(6), 1476, 2009
  5. Chetouani Y, Int. J. Reliability Safety., 4, 265, 2010
  6. Himmelblau DM, Korean J. Chem. Eng., 17(4), 373, 2000
  7. Lieftucht D, Volker M, Sonntag C, Kruger U, Irwin GW, Engell S, Control Eng. Pract., 17, 478, 2009
  8. Yoo CK, Kim DS, Cho JH, Choi SW, Lee IB, Korean J. Chem. Eng., 18(4), 408, 2001
  9. Arpornwichanop A, Kittisupakorn P, Hussain MA, Korean J. Chem. Eng., 19(2), 221, 2002
  10. Deshpande AP, Patwardhan SC, Ind. Eng. Chem. Res., 47(17), 6711, 2008
  11. Manuja S, Narasimhan S, Patwardhan S, Can. J. Chem. Eng., 86(4), 791, 2008
  12. Lu KT, Tung KL, Korean J. Chem. Eng., 22(4), 512, 2005
  13. Yang XT, Xu Q, Zhao CY, Li KY, Lou HH, Ind. Eng. Chem. Res., 48(20), 9195, 2009
  14. Kim IS, Lee KS, Koo YM, Korean J. Chem. Eng., 22(6), 830, 2005
  15. Farzi A, Mehrabani-Zeinabad A, Boozarjomehry RB, Korean J. Chem. Eng., 25(5), 955, 2008
  16. Tian WD, Wan B, Yao F, J. Beijing University of Chemical Technology., 28(1), 6, 2001
  17. Tian WD, Sun SL, Chinese J. Process Eng., 7(5), 952, 2007
  18. Tian WD, Sun SL, Wang CL, Li CK, Dynamic modeling and abnormal simulation of rectifying tower, Proceedings of the 8th World Congress on Intelligent Control and Automation, Jinan, China, 2010
  19. Katariya AM, Kamath RS, Moudgalya KM, Mahajani SM, Comput. Chem. Eng., 32(10), 2243, 2008
  20. Kim YH, Korean J. Chem. Eng., 17(5), 570, 2000
  21. Jignesh G, Gabriel R, Achim K, Frank S, Kai S, Clean Technol. Environ. Policy., 10, 245, 2008
  22. Chiang LH, Russel EL, Braatz RD, Fault detection and diagnosis in industrial systems, China Machine Press, Beijing, 2003