Simultaneous removal of cyanide and copper ions from electroplating wastewater was studied in a liquid-solid semi-fluidized ion exchanger bed. The diameter and the height of column are 20 mm and 600 mm, respectively. Strong-base anion exchange resin particles (Dowex1X8-50) were contacted with synthetic solutions containing copper and cyanide ions. Cyanide and copper ions in the solution were analyzed by a cyanide electrode and ICP (inductively coupled plasma), respectively. The ion exchange equilibrium data of Cu+ removed as cyanide-copper complexes on Dowex1X8-50 at 25℃ can be fitted with the Langmuir equation. Early leakage of cyanide from experimental loading profile data results in not only lower selectivity of free cyanide but also different seletivities of CN-Cu complexes due to the size and the structure of complexes. The optimum molar ratio (Q) between cyanide and copper ions is about 3 to obtain a reasonable removal rate of cyanide in this experimegnt.
Fagan P, Paull B, Haddad PR, Dume R, Kamar H, J. Chromatogr. A, 770, 175, 1997
Goncalves MMM, Pinto AF, Granato M, Environ. Technol., 19(2), 133, 1998
Goto M, Goto S, J. Chem. Eng. Jpn., 20(5), 417, 1987
Gupta A, "Recovery of Metal-Cyanide Complexes from Electroplating Wastewaters by Ion Exchange," Ph.D. Thesis, 1985
Hsu TL, Tran T, Young D, "Modeling of the Chemical Speciation of Cyanide Species-Application to Effluent Treatment," Ausimm Extractive Metal Con., 133, 1991
Jae WM, Hong ZD, Kim MS, Bull. Environ. Sci., 9, 1988
Jennifer BB, Ryan RL, Paziranden M, Environ. Sci. Technol., 31, 2910, 1997