Issue
Korean Journal of Chemical Engineering,
Vol.15, No.6, 637-643, 1998
Removal and Recovery of Heavy Metal Ions in Fixed and Semi-Fluidized Beds
Uptakes of heavy metal ions such as Pb2+ and Ni2+ were studied experimentally in fixed and semifluidized beds packed with a strong cation exchange resin, Amberlite 200. Single and binary aqueous solutions of lead and nickel ions were passed through ion exchange columns, and the exit concentrations were measured to get the breakthrough behavior of the ions. From the exit concentration profiles, the breakthrough time and the ion exchange capacity were evaluated. After ;removal of heavy metal ions from binary solution of lead and nickel ions until the breakthrough time, two metal ions were recovered by precipitation and resolubilization of lead. In this paper, the recovery yield and separation efficiency are rigorously discussed.
[References]
  1. Anderson RE, "Ion Exchange Separations in Handbook of Separation Technique for Chemical Engineers," Section 1.12, McGraw-Hill, New York, 1988
  2. Clifford D, Ind. Eng. Chem. Fundam., 21, 141, 1982
  3. Davidson JF, Harrison D, "Fluidization," Academic Press, London, p. 36, 1977
  4. Fan LT, Yang YC, Wen CY, AIChE J., 6, 482, 1960
  5. Fan LT, Yang YC, Wen CY, AIChE J., 5, 407, 1959
  6. Hass CN, Tare V, React. Polym., 2, 61, 1984
  7. Hwang SJ, Lu WJ, Ind. Eng. Chem. Res., 34(4), 1434, 1995
  8. Lee K, Hong J, AIChE J., 41(12), 2653, 1995
  9. Maruyama T, Hannah SA, Cohen JH, Water Pollut. Control Fed. J., 47, 962, 1975
  10. Patterson JW, "Wastewater Treatment Technology," Ann Arbor Science, Ann Arbor, 1975
  11. Singh AN, Kesavan S, Gupta PS, Int. J. Heat Mass, 23, 279, 1980