Issue
Korean Journal of Chemical Engineering,
Vol.15, No.1, 71-77, 1998
ON-LINE MONITORING AND QUANTITATIVE ANALYSIS OF BIOFOULING IN LOW-VELOCITY COOLING WATER SYSTEM
To monitor and analyze the biofouling phenomenon caused primarily by microbial suspended solids (MSS), a ’biofouling tube’ apparatus consisting of a carbon steel tube, a differential pressure transmitter, a corrator, and a cooling water circulation device was designed and fabricated. By measuring continuously the pressure drop across the biofouling tube and using the correlation between the fluid’s friction factor and surface roughness, we quantitatively analyzed the influence of MSS concentration, temperature, and fluid velocity on the rate of biofilm growth on the metal surface. The result indicated that the fluid velocity had the most profound impact, e.g., lowering the linear velocity from 0.3 to 0.15 m/sec resulted in about a four times higher biofouling rate. Up to 50 ppm MSS, the biofouling rate was proportional to the MSS concentration. The biofouling rate at 35℃ was about 1.75 times higher than that of 45℃, probably due to the diminishing effect of thermolabile microorganisms exposed at 45℃. It was also demonstrated that the biofouling could be significantly reduced by incorporating cooling water treatment programs such as protective prefilming and adding corrosion inhibitors. This apparatus, if installed on-site at a sidestream of a cooling water system, could be used to monitor the biofouling tendency on-line and to suggest timely preventive maintenance actions.
[References]
  1. Busscher HJ, Weerkamp AH, Fems Microbiol. Rev., 46, 165, 1987
  2. Cheremisinoff PN, "Handbook of Water and Wastewater Treatment Technology," Marcel Dekker, New York, 539, 1995
  3. Colturi TF, Kozelski KJ, Mater. Performance, 23(8), 43, 1984
  4. Coulson JM, Richardson JF, Sinnott RK, "Chemical Engineering," Pergamon Press, New York, 6, 511, 1989
  5. Epstein N, Heat Transf. Eng., 4, 43, 1983
  6. Geesey GG, Lewandowski Z, Flemming HC, "Biofouling and Biocorrosion in Industrial Water Systems," CRC Press, Florida, 1994
  7. Hamilton WA, Ann. Rev. Microbiol., 39, 195, 1985
  8. Marcus P, Oudar J, "Corrosion Mechanisms in Theory and Practice," Marcel Dekker Inc., 457, 1995
  9. Nevers ND, "Fluid Mechanics for Chemical Engineers," 2nd ed., McGraw-Hill, 178, 1991
  10. Pope DH, Duquette DJ, Johannes AH, Wayner PC, Mater. Performance, 23(4), 14, 1984
  11. Sanatgar H, Somerscales EFC, Chem. Eng. Prog., 53, 1991
  12. Taborek J, Aoki T, Ritter RB, Palem JW, Knudsen JG, Chem. Eng. Prog., 68, 56, 1972
  13. Tatnall RE, Mater. Performance, 20(9), 32, 1981
  14. Tatnall RE, Mater. Performance, 20(8), 41, 1981
  15. Thierry D, Mater. Performance, 26(5), 35, 1987
  16. Uchida T, Nishiyama T, Kawamura T, "Up-to-data Problems in Alkaline Cooling Water Treatment Program," Corrosion/90, NACE, Paper No. 349, 1990
  17. Wakamatsu Y, Ono Y, Yoshihara K, Kawamura F, "New Real-time Monitoring System for Improvement of Cooling Water Treatment Performance-Case History," Corrosion/91, Paper No. 481, NACE, 1991
  18. Walker CK, Maddux GC, Mater. Performance, 28(5), 64, 1989
  19. Welty JR, Wicks CE, Wilson RE, "Fundamentals of Momentum, Heat, and Mass Transfer," 3rd ed., Oregon, 202, 1984