In order to develop a reliable system of a ceramic filter for particulate collection at high temperatures like Pressurized Fluidized Bed Combustion (PFBC), an experimental study was carried out to observe the characteristics of the ceramic filter utilizing a simple block weigh-down. One block weigh-down fixes four commercial filter elements coincidentally by pressing down the individual venturi diffuser. Its operational performance was investigated in the temperature range of 600-800 degrees C in a bench scale unit using oil combustion gas into which fly ash was fed. The transient aspects of the temperature and pressure in the pulse cleaning system were also observed during the pulse cleaning.
Clift R, Seville JPK, Kuile JWW, "Rigid Ceramic Media for Filtering Hot Gases," Filtration & Separation, July/August, 265, 1989
Ciliberti DF, Boro M, Lippert TE, "Filter Unit for Use at High Temperatures," U.S. Patent, 4,735,638, April 5, 1988
Choi JH, Ji PS, Chung JD, "Technical Evaluation of Current HTHP Gas Particulate Collectors for IGCC," Proceedings of the 3rd International Symposium on COAL COMBUSTION-Science and TEchnology, September 8-21, Beijing, China, 514, 1995
Choi JH, Park KW, Keum SM, Chung JH, "Measurement of Transient Phenomena During the Pulse Cleaning of the Ceramic Filter Unit," Proceedings on Second Korea-China Joint Workshop on Coal & Clean Energy Utilization Technology, Taejon, Korea, November 2-6, 167, 1998
Durst M, Freude E, Schulz K, Walch A, "Schumacher's Hot Gas Filter Technology," Private report, March, 1996
Grimethorpe PFBC Establishment, "Grimethorpe High Temperature High Pressure Gas Filter Experiment Program," EPRI TR-100499, 2, 3, 1992