Korean Journal of Chemical Engineering, Vol.34, No.7, 1889-1895, 2017
Preparation of cationic functional polymer poly(Acryloxyethyltrimethyl ammonium chloride)/SiO2 and its adsorption characteristics for heparin
Ion-exchange is a widely used purification technology in the heparin manufacturing process. To improve the rate and efficiency, the cationic monomer Acryloxyethyltrimethyl ammonium chloride (DAC) was grafted on silica gel particles by using a surface-initiated graft-polymerization technique, and a novel adsorption polymer of PDAC/SiO2 was prepared. The adsorption experiments of PDAC/SiO2 for heparin show that there are strong electrostatic interactions between heparin with a high density of negative charges and PDAC/SiO2 that exists in many quaternary ammonium cations. Comparing the adsorption kinetics of PDAC/SiO2 with D201 anionic strong alkali exchange resin, PDAC/SiO2 shows higher adsorption capacity and faster adsorption rate. The pH and temperature of solutions have a great influence on the adsorption amount, and there is a maximum adsorption capacity of 121mg/g when pH=7 at 25 °C. The adsorption of PDAC/SiO2 for heparin is an exothermic process and driven by entropy.
[References]
- Hirsh J, Raschke R, Chest., 126, 188S, 2004
- Cosmi B, Palareti G, Thromb. Res., 29, 388, 2012
- Wittfooth S, Tertti R, Lepantalo M, Porela P, Qin QP, Tynjala J, Inkinen O, Perttila J, Airaksinen KEJ, Pettersson K, Clin. Chim. Acta, 412, 376, 2011
- Sask KN, McClung WG, Berry LR, Chan AKC, Brash JL, Acta Biomater., 7, 2029, 2011
- Durdureanu-Angheluta A, Uritu CM, Coroaba A, Minea B, Doroftei F, Calin M, Maier SS, Pinteala M, Simionescu M, Simionescu BC, J. Biomed. Nanotechnol., 10, 131, 2014
- Nelson RM, Venot A, Bevilacqua MP, Linhardt RJ, Stamenkovic I, Annu. Rev. Cell. Dev. Biol., 11, 601, 1995
- Rider CC, Coombe CR, Harrop HA, Hounsell EF, Bauer C, Feeney J, Mulloy B, Mahmood N, Hay A, Parish CR, Biochemistry, 33, 6971, 1994
- Cui H, Hung AC, Freeman C, Narkowicz C, Jacobson GA, Small DH, J. Neurochem., 123, 447, 2012
- Sasisekharan R, Shriver Z, Thromb Haemost., 102, 854, 2009
- Banga J, Tripathi CKM, New Biotechnology, 26, 99, 2009
- Zang HC, Wang JF, Li L, Zhang H, Jiang W, Wang FS, Spectroc. Acta Pt. A-Molec. Biomolec. Spectr., 109, 8, 2013
- Cai C, Edgar K, Liu J, Linhardt RJ, Carbohydr. Res., 372, 30, 2013
- Schmer G, US Patent, No. 4122250 (1978).
- Li Y, Chen T, Gao B, Qiao Z, Korean J. Chem. Eng., 31(5), 896, 2014
- Tang EJ, Cheng GX, Ma XL, Powder Technol., 161(3), 209, 2006
- Ngo VG, Bressy C, Leroux C, Margaillan A, Polymer, 50(14), 3095, 2009
- Yang B, Solakyildirim K, Chang Y, Linhardt RJ, Anal. Bioanal. Chem., 399, 541, 2011
- Flengsrud R, Larsen ML, Odegaard OR, Thromb. Res., 129, e409, 2010
- Gunay NS, Robert JL, J. Chromatogr. A, 1014, 225, 2003
- Gao BJ, Gao YC, Li YB, Chem. Eng. J., 158(3), 542, 2010
- Cestari AR, Vieira EFS, Mattos CRS, J. Chem. Thermodyn., 38(9), 1092, 2006
- dos Anjos FSC, Vieira EFS, Cestari AR, J. Colloid Interface Sci., 253(2), 243, 2002
- Cestari AR, Vieira EFS, Mattos CRS, J. Chem. Thermodyn., 38(9), 1092, 2006
- Zhang YY, Gao BJ, Xu ZQ, J. Phys. Chem. B, 117(18), 5730, 2013
|